Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13662901
- Product Categories
- Friendly Links
Information Name: | Production and supply of square cross-flow cooling tower FRP cooling towers |
Published: | 2015-03-06 |
Validity: | 800 |
Specifications: | 500T |
Quantity: | 10.00 |
Price Description: | |
Detailed Product Description: | Square tower structure features: 1. Design Features: square cooling tower square design using a small field area, with buildings, beautiful shape, large cooling capacity, can use multiple combinations. 2. tower: the use of FRP composite materials (commonly known as FRP) made of gel coat and paint surfaces using imported raw materials, the color seed contains UV stabilizers, tower up to the mirror surface, anti-aging, long Youyou Guang Ze. 3. Blade: multi-axial flow fan blade design, the senior cast aluminum alloy, the balance correction, smooth quiet operation, low noise, energy province, the blade angle is adjustable, the need to follow the wind, adjust fan blade angle, maximum ventilation effect. 4. Electric motors: a fully sealed cooling tower dedicated motor, 380V / 3Φ / 50Hz, good waterproof performance, can be safely used in humid environments. Fan motor square counterflow cooling tower uses four large for one group, a damage does not affect the normal operation of other combinations. 5. sprinkler system: water distribution system uses U-shaped pipes, nozzles more uniform, fog and strong, complete, good heat exchange cooling effect. 6. steel: galvanized metal structures and corrosion protection paint double, it greatly improves the corrosion resistance of metal components to improve the service life. Cooling tower design using the latest technology, floating less water, low noise, easy maintenance, elaborate cooling tower components, structural lightweight, easy to assemble, durable, cooling tower performance by the test, the effect is very good. Description: 1, the standard design conditions: dry bulb temperature 31.5 ℃, wet bulb temperature 28 ℃, atmospheric pressure 99400Pa, water temperature 42 ℃, water temperature 32 ℃; 2, can be combined into a variety of multiple parallel water cooling tower group; 3, the structure itself gives the product excellent low noise performance (no rain filler end zone, so there is no dripping noise); 4, vertical mounting height is low, apply to certain special places; 5, using a large wing-type fasting structure diameter, large area, low-speed, low dynamic pressure FRP fan blades, the use of such cooling towers with energy saving, low noise notable feature; 6, ultra-low-noise cooling tower at inlet and outlet set up efficient noise reduction device, so that the same level of cooling Tower effective noise reduction up to 5dB (A); 7, the use of trough water distribution systems, water distribution uniformity, clogging; 8, tricking filler itself with honeycomb or water, close the water with excellent results, so that the cooling tower Gone water losses to less than 0.01%; 9, simple structure, low weight, the top set maintenance platform, more convenient maintenance and overhaul; Installation Notes 1, should be placed in a clean, well-ventilated place. 2, the cross-flow inlet tower were installed by both sides, and is connected to the tank with the user should set the valve in place to take over for regulating flow. Can be introduced into the water by the following dry pipe, dry pipe can be put on the tower, then its pipe supports should fall on the side of the tower rack. Optional outlet pipe into the wind direction either take out the tank from the bottom. 3, safe and should be used to adjust the roundness of the hairdryer, and the tip of the tower wall gap equal and less than 10mm. The blade angle to be adjusted to the same. The method for adjusting the blade near the tip of 150mm, before and after each of the two edges of each blade to make a mark, and then measuring the distance between the front and rear edges of each blade are respectively lower chord by a bracket, in order to calculate the respective front and rear edges of the blades which point By adjusting the height several times so that the height difference is qualified to reach consensus. 4, should be avoided in the dusty floor, field institutes acidic gases, otherwise it will lead to heat exchangers and pipe corrosion. 5, the distance between the cooling tower and walls between the air inlet as follows: single-tower type is 2 meters, the twin towers type is 2.5 m, 3.5 m three-tower type is, more than four towers should be 5 meters above the height of the wall should be avoided lower than the overall height of the tower. 6 from the exhaust port of the cooling tower and the obstructions should be 5 m or more. |
Admin>>>
You are the 5808 visitor
Copyright © GuangDong ICP No. 10089450, Cooling Tower Co., Ltd. Guangdong Jia Ming All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 5808 visitor
Copyright © GuangDong ICP No. 10089450, Cooling Tower Co., Ltd. Guangdong Jia Ming All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility